Table of Contents

2WCOM FM01

The 2wcom FlexMon FM01 FM monitoring receiver combines demodulation, source-switching and FM/RDS parameter measurement/monitoring functionality. Its dual inputs can receive FM signals for rebroadcasting, monitoring, backup and alarming scenarios. An internal switch matrix changes between the inputs triggered by several states.

This connector retrieves information from the device via SNMP.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x -

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.
  • Device address: This is not required.

SNMP Settings:

  • Port number: 161
  • Get community string: public
  • Set community string: private

How to use

The element consists of the following data pages:

  • General: Displays general parameters such as the delta frequency and M/MPX signal. Also allows you to set the Polling Mode to either VMA or FM01.
  • Tuning: Contain the Station Table as well as information such as the current station and frequency.
  • Alarms: Displays the current state (OK or Alarm) of several monitored parameters.