ADVA Optical Networking FSP3000 5WCA-PCN-16GU
About
The ADVA Optical Networking FSP3000 is an optical data transport solution. This connector can be used to monitor and control a 5WCA-PCN-16GU card.
The ADVA Optical Networking FSP3000 is an extensible chassis with multiple slots. Each slot can contain a different type of extension card. This connector is especially meant for the 5WCA-PCN-16GU card.
This connector requires an element of protocol "ADVA Optical Networking FSP3000" with the same polling IP to function. The purpose of that element is to retrieve the entity IDs of the different components on this card, i.e., channels. The entity ID is used in the SNMP OID in order to successfully retrieve data from this card.
All information is retrieved using the SNMP protocol.
Installation and configuration
Creation
SNMP Main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
- Device address: Required. Format: "<chassis id>.<slot id>", e.g., "1.5".
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device (default value: public).
- Set community string: The community string used when setting values on the device (default value: private).
Configuration
No additional configuration is necessary in the element.
Usage
General
This page contains general information of the device, such as the name and temperature. Additionally, the most important statuses of the different channels that are managed by this card are available on this page.
Channel x page
The information of each channel is displayed on a separate page. Each channel contains at least the following parameters:
- Admin State
- Operational State
- Secondary States
- Facility Type
- Alias
- ALS
- Wavelength
- Fiber Type
- Frequency
- Connector
- Connectivity Type
Some of the channels also display configuration parameters.
Embedded Web Server
Displays the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.