AVT Magic SDC EDI Converter
This connector makes it possible to monitor an AVT Magic SDC EDI Converter with SNMPv2. All parameters retrieved are displayed in several pages depending on the kind of parameters. Also all traps generated by the device are captured and used to update the parameters.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version. | - | - |
| 1.0.1.x [SLC Main] | - Updated DCF version. - Changed type string to fit units. - Additional minor fixes |
1.0.0.4 | - New DCF version increases the minimum DataMiner version. - Changing type of parameter affects versioning. |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | Yes | Yes | - | - |
| 1.0.1.x | Yes | Yes | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination. (default: 161).
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
How to use
The element consists of the data pages described below. Each table is updated based on traps.
- General: Contains general information such as the Firmware Version and Temperature.
- E1: Displays three tables with information about E1-related Input States, Levels and Output States.
- EDI: Contains a table with the EDI Input States Overview.
- ETI: Contains a table with the ETI Input States Overview.
- DAB: Contains a table with Reconfig States.
- SDC: Contains a table with SDC Input States, as well as information about SDC Seamless and about Switch Events.
DataMiner Connectivity Framework
The 1.0.1.x connector range of the AVT Magic SDC EDI Converter connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Physical fixed interfaces:
- E1 Input 1: Created parameter E1 Input 1 Overall State for this interface of type in.
- E1 Output 1: Created parameter E1 Output 1 Overall State for this interface of type out.
- E1 Input 2: Created parameter E1 Input 2 Overall State for this interface of type in.
- E1 Output 2: Created parameter E1 Output 2 Overall State for this interface of type out.
- Clock 1 (1pps clock): Created parameter Clock 1 Dummy Parameter for this interface of type in.
- Clock 2 (10 MHz clock): Created parameter Clock 2 Dummy Parameter for this interface of type in.
- LAN 1: Can be used as EDI Input 1, so created parameter EDI Input 1 Overall State for this interface of type in.
- LAN 2: Can be used as EDI Input 2, so created parameter EDI Input 2 Overall State for this interface of type in.
Connections
Internal Connections
- E1 Input 2: connected internally to E1 Output 1 and E1 Output 2.