Advantech AMT MC 160-250L12-100
About
The Advantech AMT MC 160-250L12-100 is a monitor and control panel for redundant amplifiers.
The monitor and control panel is used for redundant high-power amplifiers, monitoring the status of two units in a redundant system and providing control to the amplifiers. It can monitor three slave SSPA units continuously, collecting and updating information, as well as controlling these SSPAs when required. In other words, the monitor and control panel can control any slave system connected to it, such as the redundant 1:2 SSPA system.
Installation and configuration
Creation
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Direct connection:
- Baudrate: Baudrate specified in the manual of the device.
- Databits: Databits specified in the manual of the device.
- Stopbits: Stopbits specified in the manual of the device.
- Parity: Parity specified in the manual of the device.
- FlowControl: FlowControl specified in the manual of the device.
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
- Bus address: The bus address of the device.
Usage
General
This page contains some general parameters of the Control Panel, such as the Serial Number, Shroud Temperature and the two Power Supply Voltages.
In addition, the page contains the Reset Main Control Board button, the Switches Alarm and the Connection Status, as well as the Redundancy Status and Mode.
SSPA Unit A
This page displays the SSPA Unit A Status, Transmission Status, Mute/Unmute Condition, Attenuation, Transmission and Reflected Power, ALC Value, Elapsed Time, Low Power Threshold, Communication, Fault and Power Status, Alarm Summary, ALC High, and Low and Suspended Alarms. In addition, it also displays the Shroud and Hot Spot Temperature, P/S Voltage, Current, Serial Number, Software Revision Number, Unit Version, Device Type, Power Class and Frequency Band.
SSPA Unit B
This page contains the same parameters as the SSPA Unit A page, but instead related to Unit B.
SSPA Unit S
This page contains the same parameters as the SSPA Unit A page, but instead related to Unit S.