Astro U261
With this connector, it is possible to gather and view information from the Astro U261 and to configure this device.
About
This connector uses HTTP to monitor the Astro U261. The connector also has an SNMP interface to receive traps from the device.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version | Yes | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | 4881 |
Installation and configuration
Creation
This connector uses two interfaces: an HTTP interface to retrieve the data and an SNMP interface to collect the traps.
The connector is implemented to support direct HTTP communication with the Astro U261 device, but it also supports proxy communication if necessary.
In either case, the SNMP interface collects the traps sent by the device, so the SNMP IP address must be the IP address of the device.
HTTP Connection for Direct Communication
- IP address/host: The IP address of the U261.
- IP port: The port of the destination, e.g., 80.
- Bus address: This field can be used to bypass the proxy. To do so, fill in the value ByPassProxy.
SNMP Connection
- IP Address/host: The polling IP of the U261, e.g., 10.11.12.13.
- Port number: The port of the connected device, by default 161.
- Get community string: The community string in order to read from the device. The default value is public.
- Set community string: The community string in order to set to the device. The default value is private.
Configuration
When a new element is created, no further configuration is necessary to poll information from the device without authentication.
However, to perform sets on the devices, you must configure the Username and Password credentials on the Login page of the element. The default credentials are Username: admin and Password: astro.
Usage
General
This page displays general information about the device.
The credentials required to perform sets on the device can be filled in via the Login page button (see Configuration section above).
The Licensing settings are available at the bottom of the first column. This section contains information on the licensed equipment and features.
With the input mask, you can insert and activate the acquired license keys by selecting the option Submit.
Several buttons are also available that allow you to save the current settings, load default settings or reboot the system to the operating parameters saved in the flash memory.
Status
This page displays the status of the device, including the Memory and CPU Load.
Main
On this page, you can access the main configuration of the device. This configuration consists of IP Management Settings (e.g., DNS, Time Source, Management Channels configurations, ...) and IP Data Settings (Data Channels Configurations and Status).
TestGen
On this page, the test generator settings can be configured (e.g., Data Rate and Packet Id).
IP RX Status
On this page, you can find information on the current configuration and statistics for the 16 receivers (e.g., Selected Port, Service Info, Data Rate, ...).
IP RX Settings
On this page, you can configure communication settings of the 16 receivers (e.g., Source IP/Port, Encapsulation, Priority, ...).
IP TX1 Settings
On this page, you can configure the output IP transmitter settings (e.g., Destination IP/Port, TOS, TTL, FEC configs, ...).
Input MUX
On this page, you can route the input IP receiver signal, ASI TP input or input test signal to the output IP transmitter channel. The page also allows you to perform settings on the ASI TP Input.
DVB ASI Outputs Settings
On this page, the ASI outputs can be configured (e.g., State, Packet Length, ...).
Output MUX
This page displays a matrix which can be used to establish connections between the system inputs (IP receivers, ASI TP and test signal) and the DVB ASI outputs of the system. The same input can be connected to multiple outputs.
Update/Config
On this page, you can perform a software update. The Astro MIB files, the log file and the device status/configuration files can also be downloaded on this page.
System Log
This page contains a table listing all the log entries. To access the log settings, click the System Log Config page button.
Active Alarms
This page displays a table with the current alarms on the device.
Network
This page displays network parameters. Note that these parameters are retrieved via SNMP. Polling for these parameters can be enabled or disabled using the Network Data Polling toggle button.
Web Interface
This page displays the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
DataMiner Connectivity Framework
DCF is supported in the connector range 1.0.0.x, from the initial version onwards. The connector can only be used on a DMA with 9.0.0 [CU6] as the minimum version.
Interfaces
Fixed Interfaces
- ASI TP Input (type: in).
Dynamic Interfaces
The Ethernet data ports are full duplex, which means that they work as inputs in reception mode and outputs in transmission mode.
- Ethernet Data Inputs (Data A and Data B) (type: in).
- IP TX1 Ethernet Data Outputs (Data A and Data B) (type: out).
- DVB ASI Outputs (ASI 1 .. 16) (type: out).
Connections
Internal Connections
Internal Connections between the system inputs (Ethernet Data Inputs and ASI TP) and the system outputs (IP TX Ethernet Data Outputs and DVB ASI Outputs) are mapped and characterized by the following connection properties: Input Receiver, TS-ID, ONID, Alias, Reception IP:Port, Source IP and Destination IP:Port.