Table of Contents

Axon ACP - GDR26

The GDR26 is a 3 Gb/s, HD and SD dual-input distribution amplifier with 3 reclocked outputs per channel (ASI/DVB compatible).

The Axon ACP - GDR26 connector can be used to display and configure information related to this device.

About

This connector is automatically generated by the connector Axon ACP.

There are different possibilities available for alarm monitoring and trending.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.2.x Change in export rules. Yes Yes
1.0.3.x Change in discrete display values. Yes Yes

Product Info

Range Supported Firmware Version
1.0.2.x 0700
1.0.3.x 0700

Installation and configuration

Creation

This element is automatically created by the parent element using the Axon ACP connector.

Usage

This element has the following data pages:

  • General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
  • I/O
  • Settings
  • Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.

DataMiner Connectivity Framework

The Axon ACP connector supports the usage of DCF.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Connectivity for this protocol is managed by the parent protocol Axon ACP.

Interfaces

Physical Interfaces

  • SDI Input A: A single fixed interface of type input.
  • SDI Input B: A single fixed interface of type input.
  • SDI Output A1: A single fixed interface of type output.
  • SDI Output A2: A single fixed interface of type output.
  • SDI Output A3: A single fixed interface of type output.
  • SDI Output B1: A single fixed interface of type output.
  • SDI Output B2: A single fixed interface of type output.
  • SDI Output B3: A single fixed interface of type output.

Virtual Interfaces

  • Reclocker 1: A single fixed interface of type inout.
  • Reclocker 2: A single fixed interface of type inout.

Connections

Internal Connections

When a DVE child element is created, the following connections are established:

  • Between Reclocker 1 and SDI Output A1.
  • Between Reclocker 1 and SDI Output A2.
  • Between Reclocker 1 and SDI Output A3.
  • Between Reclocker 2 and SDI Output B1.
  • Between Reclocker 2 and SDI Output B2.
  • Between Reclocker 2 and SDI Output B3.

Depending on the state of the Input Selection, the following connections are established:

  • Normal:

  • Between SDI Input A and Reclocker 1.

    • Between SDI Input B and Reclocker 2.
  • Crossed:

  • Between SDI Input A and Reclocker 2.