Axon ACP - HXH40
The HXH40 is an HD up-/down-/cross- & standards converter.
The Axon ACP - HXH40 connector can be used to display and configure information related to this device.
About
This connector is automatically generated by the connector Axon ACP.
There are different possibilities available for alarm monitoring and trending.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.2.x | Change in export rules. | Yes | Yes |
| 1.0.3.x | Change in discrete display values | Yes | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.2.x | 1824, 1926 |
| 1.0.3.x | 1824, 1926 |
Installation and configuration
Creation
This element is automatically created by the parent element using the Axon ACP connector.
Usage
This element has the following data pages:
- General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
- Status
- Audio Status
- I/O
- Video
- Audio
- Embedder
- Settings
- Up Conversion
- Down Conversion
- Cross Conversion
- Standard Conversion
- Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.
DataMiner Connectivity Framework
The Axon ACP connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Connectivity for this protocol is managed by the parent protocol Axon ACP.
Interfaces
Physical Interfaces
- SDI Input: A single fixed interface of type input.
- REF Input 1: A single fixed interface of type input.
- REF Input 2: A single fixed interface of type input.
- SDI Output 1: A single fixed interface of type output.
- SDI Output 2: A single fixed interface of type output.
- SDI Reclocked Output: A single fixed interface of type output.
- SYNAPSE Bus 1: A single fixed interface of type output.
- SYNAPSE Bus 2: A single fixed interface of type output.
- SYNAPSE Bus 3: A single fixed interface of type output.
- SYNAPSE Bus 4: A single fixed interface of type output.
Connections
Internal Connections
When a DVE child element is created, the following connections are established:
- SDI Input and SDI Output 1.
- Between SDI Input and SDI Output 2.
- Between SDI Input and SDI Reclocked Output.
- Between SDI Input and SYNAPSE Bus 1.
- Between SDI Input and SYNAPSE Bus 2.
- Between SDI Input and SYNAPSE Bus 3.
- Between SDI Input and SYNAPSE Bus 4.
Depending on the state of the Reference Input, the following connections are established:
1:
Between REF Input 1 and SDI Output 1.
- Between REF Input 1 and SDI Output 2.
2:
Between REF Input 2 and SDI Output 1.
- Between REF Input 2 and SDI Output 2.