Table of Contents

Axon ACP GDR216

The GDR216 is a 3 Gb/s, HD and SD dual-input distribution amplifier with 8 reclocked outputs per channel (ASI/DVB compatible).

The Axon ACP GDR216 connector can be used to display and configure information related to this device.

About

This connector can be automatically generated by the connector Axon ACP.

There are different possibilities available for alarm monitoring and trending.

Version Info

Range Key Features Based on System Impact
1.0.0.x Initial version [SLC Main] - -

Product Info

Range Supported Firmware
1.0.0.x 0600, 0800

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x Yes Yes - -

Installation and configuration

Creation

The element using this connector can be automatically created by the parent element using the Axon ACP connector, but it can also be a standalone element.

Connections

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device, being the slot number of the card.

Serial Broadcast Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device.

Usage

This element has the following data pages:

  • General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
  • SFP
  • Status
  • Settings
  • HDMI/CVBS
  • Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.

DataMiner Connectivity Framework

The Axon ACP connector supports the usage of DCF.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Interfaces

Physical Interfaces

  • SDI Input A: A single fixed interface of type input.
  • SDI Input B: A single fixed interface of type input.
  • SDI Output A1: A single fixed interface of type output.
  • SDI Output A2: A single fixed interface of type output.
  • SDI Output A3: A single fixed interface of type output.
  • SDI Output A4: A single fixed interface of type output.
  • SDI Output A5: A single fixed interface of type output.
  • SDI Output A6: A single fixed interface of type output.
  • SDI Output A7: A single fixed interface of type output.
  • SDI Output A8: A single fixed interface of type output.
  • SDI Output B1: A single fixed interface of type output.
  • SDI Output B2: A single fixed interface of type output.
  • SDI Output B3: A single fixed interface of type output.
  • SDI Output B4: A single fixed interface of type output.
  • SDI Output B5: A single fixed interface of type output.
  • SDI Output B6: A single fixed interface of type output.
  • SDI Output B7: A single fixed interface of type output.
  • SDI Output B8: A single fixed interface of type output.

Virtual Interfaces

  • Reclocker A: A single fixed interface of type inout.
  • Reclocker B: A single fixed interface of type inout.

Connections

Internal Connections

When a DVE child element is created, the following connections are established:

  • Between Reclocker A and SDI Output A1.
  • Between Reclocker A and SDI Output A2.
  • Between Reclocker A and SDI Output A3.
  • Between Reclocker A and SDI Output A4.
  • Between Reclocker A and SDI Output A5.
  • Between Reclocker A and SDI Output A6.
  • Between Reclocker A and SDI Output A7.
  • Between Reclocker A and SDI Output A8.
  • Between Reclocker B and SDI Output B1.
  • Between Reclocker B and SDI Output B2.
  • Between Reclocker B and SDI Output B3.
  • Between Reclocker B and SDI Output B4.
  • Between Reclocker B and SDI Output B5.
  • Between Reclocker B and SDI Output B6.
  • Between Reclocker B and SDI Output B7.
  • Between Reclocker B and SDI Output B8.

Depending on the state of Active A, the following connections are established:

  • Input A: Between SDI Input A and Reclocker A.
  • Input B: Between SDI Input B and Reclocker A.

Depending on the state of Active B, the following connections are established:

  • Input A: Between SDI Input A and Reclocker B.
  • Input B: Between SDI Input B and Reclocker B.