Axon ACP GNS600
The GNS600 is a dual-channel 3 Gb/s, HD up-converter with color corrector and optional cross-input audio shuffler.
The Axon ACP GNS600 connector can be used to display and configure information related to this device.
About
This connector can be automatically generated by the connector Axon ACP Frame Manager.
There are different possibilities available for alarm monitoring and trending.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version | - | - |
| 1.0.1.x [SLC Main] | Additional SNMP connection | 1.0.0.5 | Additional SNMP connection must be configured |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 1407 2109 3112 |
| 1.0.1.x | 1407 2109 3112 3213 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | Yes | Yes | - | - |
| 1.0.1.x | Yes | Yes | - | - |
Installation and configuration
Creation
The element using this connector can be automatically created by the parent element using the Axon ACP Frame Manager connector, but it can also be a standalone element.
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- Bus address: The bus address of the device, being the slot number of the card.
Serial Broadcast Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- Bus address: The bus address of the device.
SNMP Broadcast Connection
This connector uses an SNMP connection and requires the following input during element creation:
SNMP CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
Usage
The element has the following data pages:
- General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
- Status: This page contains IO delay and slot status information.
- Video Status
- S2010 Status
- SCTE104 Status
- S2031-OP47-WST Status
- GPI Mode Status
- Video
- Delay
- S2010
- SCTE104: This page contains the Transcoder subpage, with VANC transcoder information.
- S2016
- S2031-OP47-WST
- GPI Mode
- Teletext: This page contains the AODB subpage, with Axon Open Data Bridge protocol information.
- X31
- Network
- Network Status
- Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.
DataMiner Connectivity Framework
The Axon ACP connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Physical Interfaces
- SDI Input 1: A single fixed interface of type input.
- SDI Input 2: A single fixed interface of type input.
- SDI Input 3: A single fixed interface of type input.
- SDI Input 4: A single fixed interface of type input.
- SDI Output 1: A single fixed interface of type output.
- SDI Output 2: A single fixed interface of type output.
- SDI Output 3: A single fixed interface of type output.
- SDI Output 4: A single fixed interface of type output.
Virtual Interfaces
- Internal Switch: A single fixed interface of type inout.
Connections
Internal Connections
Dynamic Connections
- Between SDI Input 1 and Internal Switch.
- Between SDI Input 2 and Internal Switch.
- Between SDI Input 3 and Internal Switch.
- Between SDI Input 4 and Internal Switch.
Fixed Connections
- Between Internal Switch and SDI Output 1.
- Between Internal Switch and SDI Output 1.
- Between Internal Switch and SDI Output 1.
- Between Internal Switch and SDI Output 1.