Axon ACP GXG400
The GXG400 is a high-end up-/down-/cross-converter.
This connector can be used to display and configure information related to this device.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version [SLC Main] | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 0606 2426 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | Yes | Yes | - | - |
Configuration
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address of the device, which is the slot number of the card.
Serial Broadcast Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address of the device, which is the slot number of the card.
How to use
The element has the following data pages:
General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
SFP
Add-On
Status
I/O Status
I/O
GPI/O
Video: This page displays settings for video configuration and has multiple subpages:
Up Converter: Allows you to configure and set upconverter presets.
- Down Converter: Allows you to configure and set downconverter presets.
- Cross Converter: Allows you to configure and set crossconverter presets.
- Transparent: Allows you to configure and set transparent pass presets (with ARC function).
- Inserter: Allows you to configure and set simultaneous Vi, WSS, and AFD (S2016) insertion presets.
Audio
Settings
Embedder
Embedder 01/04
Embedder 05/08
Embedder 09/12
Embedder 13/16
Network
Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.
DataMiner Connectivity Framework
The 1.0.0.x range of the Axon ACP GXG400 connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Physical fixed interfaces:
- SDI Input 1: A single fixed interface of type input.
- SDI Input 2: A single fixed interface of type input.
- SDI Input 3: A single fixed interface of type input.
- SDI Input 4: A single fixed interface of type input.
- SDI Output 1: A single fixed interface of type output.
- SDI Output 2: A single fixed interface of type output.
- SDI Output 3: A single fixed interface of type output.
- SDI Output 4: A single fixed interface of type output.
Connections
Internal Connections
Depending on the state of the Input Selection A, the following connections are established:
- SDI-1: Between SDI Input 1 and SDI Output 1.
- SDI-2: Between SDI Input 2 and SDI Output 1.
- SDI-3: Between SDI Input 3 and SDI Output 1.
- SDI-4: Between SDI Input 4 and SDI Output 1.