Table of Contents

Axon ACP HXH40

The HXH40 is an HD up-/down-/cross- & standards converter.

The Axon ACP HXH40 connector can be used to display and configure information related to this device.

About

This connector can be automatically generated by the connector Axon ACP.

There are different possibilities available for alarm monitoring and trending.

Version Info

Range Key Features Based on System Impact
1.0.0.x Initial version [SLC Main] - -

Product Info

Range Supported Firmware
1.0.0.x 1824, 1926

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x Yes Yes - -

Installation and configuration

Creation

The element using this connector can be automatically created by the parent element using the Axon ACP connector, but it can also be a standalone element.

Connections

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device, being the slot number of the card.

Serial Broadcast Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device.

Usage

This element has the following data pages:

  • General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
  • Status
  • Audio Status
  • I/O
  • Video
  • Audio
  • Embedder
  • Settings
  • Up Conversion
  • Down Conversion
  • Cross Conversion
  • Standard Conversion
  • Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.

DataMiner Connectivity Framework

The Axon ACP connector supports the usage of DCF.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Interfaces

Physical Interfaces

  • SDI Input: A single fixed interface of type input.
  • REF Input 1: A single fixed interface of type input.
  • REF Input 2: A single fixed interface of type input.
  • SDI Output 1: A single fixed interface of type output.
  • SDI Output 2: A single fixed interface of type output.
  • SDI Reclocked Output: A single fixed interface of type output.
  • SYNAPSE Bus 1: A single fixed interface of type output.
  • SYNAPSE Bus 2: A single fixed interface of type output.
  • SYNAPSE Bus 3: A single fixed interface of type output.
  • SYNAPSE Bus 4: A single fixed interface of type output.

Connections

Internal Connections

When a DVE child element is created, the following connections are established:

  • SDI Input and SDI Output 1.
  • Between SDI Input and SDI Output 2.
  • Between SDI Input and SDI Reclocked Output.
  • Between SDI Input and SYNAPSE Bus 1.
  • Between SDI Input and SYNAPSE Bus 2.
  • Between SDI Input and SYNAPSE Bus 3.
  • Between SDI Input and SYNAPSE Bus 4.

Depending on the state of the Reference Input, the following connections are established:

  • 1:

  • Between REF Input 1 and SDI Output 1.

    • Between REF Input 1 and SDI Output 2.
  • 2:

  • Between REF Input 2 and SDI Output 1.

    • Between REF Input 2 and SDI Output 2.