Axon ACP SDR09
The SDR09 is a dual-channel distribution amplifier, with channel A having 3 outputs and channel B having 4 outputs. The SDR09 re-clocks the input signal to ensure stability of the outputs.
The Axon ACP SDR09 connector is used to monitor and display status information of the SDR09 card.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 0600 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | Yes | Yes | - | - |
Configuration
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address or slot number/position of the card in the frame.
Serial IP Connection - Events Connection
This connector uses a smart-serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination. Specify "any".
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address or slot number/position of the card in the frame.
How to use
The element has the following pages:
- General: Displays information about the identity of the card and other general information: Card Name, Card Description, SW Revision, HW Revision, etc.
- Amplifier: Displays the Bitrate and SDI Input parameters.
- Alarm Priority: Displays the event messages of the card, i.e., special messages generated asynchronously on the card.
DataMiner Connectivity Framework
The 1.0.0.x connector range of the Axon ACP 2IX08 connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Physical fixed interfaces:
- SDI Input A: A single fixed interface of type in.
- SDI Input B: A single fixed interface of type in.
- SDI Output A1: A single fixed interface of type out.
- SDI Output A2: A single fixed interface of type out.
- SDI Output A3: A single fixed interface of type out.
- SDI Output B1: A single fixed interface of type out.
- SDI Output B2: A single fixed interface of type out.
- SDI Output B3: A single fixed interface of type out.
- SDI Output B4: A single fixed interface of type out.
Connections
Internal Connections
- SDI Input A -> SDI Output A1.
- SDI Input A -> SDI Output A2.
- SDI Input A -> SDI Output A3.
- SDI Input B -> SDI Output B1.
- SDI Input B -> SDI Output B2.
- SDI Input B -> SDI Output B3.