Table of Contents

Axon ACP SLD100

The SLD100 is a long time SD-SDI uncompressed baseband video delay unit. It can store and delay SD material, including all blanking, as RAW data.

The Axon ACP SLD100 connector can be used to display and configure information related to this device.

About

This connector can be automatically generated by the connector Axon ACP.

There are different possibilities available for alarm monitoring and trending.

Version Info

Range Key Features Based on System Impact
1.0.0.x Initial version [SLC Main] - -

Product Info

Range Supported Firmware
1.0.0.x 1512

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x Yes Yes - -

Installation and configuration

Creation

This element can be automatically created by the element using the Axon ACP Frame Manager connector, but can also be used as a standalone connector.

Connections

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device, being the slot number of the card.

Serial Broadcast Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP or URL of the destination.
    • Bus address: The bus address of the device.

Usage

This element has the following data pages:

  • General: This page displays general information about the card: Card Name, Card Description, SW Revision, HW Revision, etc.
  • SSD
  • Status
  • GPIO
  • Marker
  • Settings
  • Network
  • Alarm Priority: This page displays the event messages of the card, i.e., special messages generated asynchronously on the card.

DataMiner Connectivity Framework

The Axon ACP connector supports the usage of DCF.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Interfaces

Physical Interfaces

  • Input SDI 1: A single fixed interface of type input.
  • Input SDI 2: A single fixed interface of type input.
  • Output SDI 1: A single fixed interface of type output.
  • Output SDI 2: A single fixed interface of type output.

Connections

Internal Connections

  • Between Input SDI 1 and Output SDI 1.
  • Between Input SDI 1 and Output SDI 2.
  • Between Input SDI 2 and Output SDI 1.
  • Between Input SDI 2 and Output SDI 2.

Depending on the state of the Input Selection, the following connections are established:

  • 0:

  • Between Input SDI 1 and Output SDI 1.

    • Between Input SDI 1 and Output SDI 2.
  • 1:

  • Between Input SDI 2 and Output SDI 1.

    • Between Input SDI 2 and Output SDI 2.