Axon ACP UXU410
The UXU410 is a high-end up-/down-/cross-converter. The card allows you to simulcast any output standard in any format from any source standard. The embedded audio is carried over to the SD, HD or 3 Gb/s domain.
The Axon ACP UXU410 connector is used to manage UXU410 Axon cards.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 1720 1925 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | Yes | Yes | - | - |
Configuration
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address or slot number/position of the card in the frame.
Serial IP Connection - Events Connection
This connector uses a smart-serial connection and requires the following input during element creation:
SMART-SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (fixed value: 2071).
- Bus address: The bus address or slot number/position of the card in the frame.
How to use
The setting of some parameters depends on other parameters' current value. For example, on the Network page, in order to set the Preferred IP Address, you need to make sure the IP Configuration is set to Manual mode. When such a parameter is not set to the correct value, a message box will be displayed. Follow the instructions in the message box and set the required parameter to the appropriate value before setting the other parameter.
DataMiner Connectivity Framework
The 1.0.0.x connector range of the Axon ACP UXU410 connector supports the usage of DCF.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Physical fixed interfaces:
- SDI Input 1: A single fixed interface of type in.
- SDI Input 2: A single fixed interface of type in.
- SDI Input 3: A single fixed interface of type in.
- SDI Input 4: A single fixed interface of type in.
- SDI Output 1: A single fixed interface of type out.
- SDI Output 2: A single fixed interface of type out.
- SDI Output 3: A single fixed interface of type out.
- SDI Output 4: A single fixed interface of type out.
Connections
Internal Connections
- SDI Input 1 -> SDI Output 1.
- SDI Input 1 -> SDI Output 2.
- SDI Input 1 -> SDI Output 3.
- SDI Input 1 -> SDI Output 4.
- SDI Input 2 -> SDI Output 1.
- SDI Input 2 -> SDI Output 2.
- SDI Input 2 -> SDI Output 3.
- SDI Input 2 -> SDI Output 4.
- SDI Input 3 -> SDI Output 1.
- SDI Input 3 -> SDI Output 2.
- SDI Input 3 -> SDI Output 3.
- SDI Input 3 -> SDI Output 4.
- SDI Input 4 -> SDI Output 1.
- SDI Input 4 -> SDI Output 2.
- SDI Input 4 -> SDI Output 3.
- SDI Input 4 -> SDI Output 4.
Notes
This connector is best combined with the Axon ACP Frame Manager connector, but it can be used as a standalone connector as well.