CEFD CDM Qx SNMP
This protocol is used to control and monitor the CEFD CDM Qx SNMP device
About
This connector uses an SNMP connection and a serial connection to communicate with the device.
The snmp connection will poll the device to retrieve the information and also allows sets to control the device.
A serial connection is used to get and set the LSR state.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial Version | No | Yes |
| 2.0.0.x | Usage of tables to handle all slots, based on 1.0.0.6 | No | Yes |
| 2.0.1.x | Add (serial) command LRS / REN, based on 2.0.0.9 | No | Yes |
| 3.0.0.x | New protocol name, based on 2.0.1.5 | No | Yes |
| 3.1.0.x | New firmware, based on 3.0.0.1 | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 3.1.0.x | FW-11247 |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- IP port: The IP port of the device.
- Get community string: The community string used when reading values from the device. (default: public)
- Set community string: The community string used when setting values on the device. (default: private)
Serial SerialPort Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
- Direct connection:
- Baudrate: Baudrate specified in the manual of the device.
- Databits: Databits specified in the manual of the device.
- Stopbits: Stopbits specified in the manual of the device.
- Parity: Parity specified in the manual of the device.
- FlowControl: FlowControl specified in the manual of the device.
- Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
- Bus address: The bus address of the device.
Usage
Main View
This page is the default page, and shows the Circuit ID, Unit Summary Alarm, and the ODU Alarms
General
This page allows the monitoring and configuration of the most important information, as the reference frequency, internal frequency, framing, AUPC, alarms and temperature.
This page also includes these page buttons:
- Grouping: This subpage displays information about the groups, as redundancy, online status and slots.
- Firmware Info: This subpage displays a table with all the information about the firmware.
- Defice info: This subpage shows the basic information about the device, as the serial number, model number, firmware revision, addresses, and traps.
- Access List: This subpage shows a table with all the allowed addresses.
- Modules: This subpage shows a table with the existing modules and their characteristics.
- Interfaces: This subpage shows information about their interfaces, RTS/CTS, G.703 and HSSI.
- Framing: This subpage shows information about the framing, EDMAC, AUPC and the "Drop and Insert plus plus" Table.
- Alarm Mask: This subpage allows masking or unmasking alarming for the Rx and Tx.
- Temperature Details: This subpage shows details about the temperature of the cards.
- LBUC: This subpage allows management of the LBUC and LLNB.
- ODU: This subpage allows the monitoring of the ODU.
Test Mode Config
This page shows a table with the test configurations of the Tx
Modulator
This page shows tables with the Status, Primary Settings and Additional Settings of the Tx
Demodulator
This page shows tables with the Status, Primary Settings and Additional Settings of the Rx
Monitor
- EventLog: This subpage shows a table with all the Stored Events received
- Stat¡stics: This subpage shows a table with all the Stored Statistics, and allows the configuration of the reception of the statistics
- Rx: This subpage shows the relevant information about the Rx, as the BER Multiplier, Buffer Fill State, Frequency Offset, Signal Level and Eb No
- CNC: This subpage shows the Slot, the Ratio, the Delay and Offset Freq of the CNC
BIST BERT Generator
This page shows information with the monitoring parameters of the BIST BERT Generator
BIST BERT Monitor
This page shows information with the monitoring parameters of the BIST BERT Monitor
Spectrum Analyzer
This page shows information with the monitoring parameters of the Spectrum Analyzer
Save / Load Configuration
This page allows to Save or Load a configuration, by saving or loading a csv file
Web Interface
This page displays the web interface of the device. The client machine has to be able to access the device. If not, it will not be possible to open the web interface.