CPI HPA SNMP

The TouchPower HPA is part of a comprehensive line of communication amplifiers comprising TWTAs, Klystron Amplifiers (KPAs) and Solid State Power Amplifiers (SSPAs). All are designed specifically for service in satellite earth stations operating in standard frequency bands.

About

Standard SNMP connector.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x Initial version Yes Yes

Product Info

Range Supported Firmware Version
1.0.0.x Not specified.

Installation and configuration

Creation

SNMP main connection

This connector uses an SNMP connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string used when reading values from the device, by default public.
  • Set community string: The community string used when setting values on the device, by default private.

Usage

General

This page displays the System Description, Contacts, and Locations.

System

This page displays the Model, Serial, Tube Model, and Tube Serial Number, as well as the Firmware Table.

Switch

This page contains two tables, the Switch Version and Amplifier State Table, with separate parameters about the switch information.

Switch Position

This page displays an overview of command toggle buttons, a page button that opens the Preset Table, and two control page buttons to go to the Priority and Position Table.

Event Control

This page displays an overview of parameters monitoring the Alarm and Fault Threshold Table.

Amplifier

This page displays an overview of parameters monitoring the Timer as well as configurable parameters for the amplifiers.

Faults

This page displays an overview of the faults.

Alarms

This page displays an overview of the alarms.

Inhibits

This page displays an overview of the inhibits.

Advanced

This page displays configurable parameters for the device, including Band Select, Life Extender Option, Run Life Extender, and Life Extender Auto Timer.

DataMiner Connectivity Framework

The 1.0.0.x connector range of the CPI HPA SNMP protocol supports the usage of DCF and can only be used on a DMA with 8.5.7 as the minimum version.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Interfaces

Fixed interfaces

Virtual fixed interfaces:

  • A virtual fixed interface named Input of type input is available, representing the input the device.
  • A virtual fixed interface named Output of type output is available, representing the Output the device.

Connections

Internal Connections

  • Connections from the input interface to the output interface.