CPI K4U74
Important note
This connector has been reviewed and is now available as a more generic connector: CPI KHPA Gen IV Series Binary Version.
Please use this new updated version instead of the version detailed below.
About
This is an obsolete connector that was used to monitor a CPI K4U74 high-power amplifier.
It uses a serial connection to monitor the state of the HPA itself and to control the waveguide switches in order to allow redundancy switching between up to 10 other HPAs.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version | - | - |
| 1.1.0.x | New firmware that uses variable response lengths | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | Front Panel Boost Kernel Software Version: 03.00.13 Front Panel Main Program Software Version: 03.01.72 Power Supply Boot Kernel Software Version: 03.00.03 Power Supply Main Program Software Version: 03.01.34 RF Controller Boot Kernel Software Version: 03.00.03 RF Controller Main Program Software Version: 03.01.42 Ext Interface Boot Kernel Software Version: 03.00.03 Ext Interface Main Program Software Version: 03.01.54 Can Communication Level Key: 03.01.22 ID Version: GEN4 2003 |
| 1.1.0.x | Front Panel Main Program Software Version: 03.01.85 Power Supply Main Program Software Version: 03.01.40 RF Controller Main Program Software Version: 03.01.46 Ext Interface Main Program Software Version: 03.01.62 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
| 1.1.0.x | No | Yes | - | - |
Configuration
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
IP address/host: The polling IP of the device, e.g., 10.11.12.13.
IP port: The port of the connected device.
Bus address: The bus address of the connected device's relay processor, ranging from 17 up to and including 255.
Web Interface
The web interface is only accessible when the client machine has network access to the product.
How to Use
The element consists of the following data pages:
General: Displays system information and information about software versions.
Measurements: Displays the values for the current, voltage, power, UPC information, and temperature.
Switch Controller: Displays information about Switch Position and Switch Controller amplifier channels.
Settings: Contains configurable parameters, such as time and amplifier settings.
Alarms: Displays the alarm status for all monitored parameters. Subpages are available with more specific alarm information.