CPI Touch Power 3RU-0 Controller
The Touch Power remote control panel design can be used either as a remote controller or as a switch remote controller that interfaces specifically with CPI amplifiers.
About
The CPI Touch Power 3RU-0 Controller connector is used to control and monitor the parameters via SNMPv2.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version | No | Yes |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 01.00.01 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device (default value: public).
- Set community string: The community string used when setting values on the device (default value: private).
How to use
General
This page displays the System Description, System Up Time, System Type, Number of Amplifiers and Firmware Version Table.
Static Configuration
This page displays configurable parameters for the device, including Priority Switching, System Installed, Drive Type, Switch on Tx Inhibit, Switch on Hv ON, Switch on Tx no Inhibit and Power Copy.
Position
This page contains a table with the switch positions. Switches from HPA1 to HPA2 should be changed jointly.
Priority
This page contains the Amplifier Priority Table, where the priority setting of the switches can be changed.
Preset
This page contains the Preset Table, which allows you to set switches to a preset using the Preset Active column.
Amplifier State
This page displays a table with information on the communication status of the amplifier and the amplifier state.
Event
This page displays information about any event that has occurred.
Web Interface
This page displays the web interface of the device. However, the web interface is only accessible when the client machine has network access to the product.
Notes
The SNMP sets on the Switch Position Table only will be executed if Switch Mode is set to Manual.