Double D Electronics DDA219-L3333
About
This connector monitors the activity of the Double D Electronics DDA219-L3333 switch controller.
The connector uses serial communication to allow the end user to control and monitor the switch configuration.
Configuration
Connections
Serial Connection — Main
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Direct connection:
- Baudrate: Baudrate specified in the manual of the device, e.g., 9600 (range: 1200 - 115200).
- Databits: Databits specified in the manual of the device, e.g., 7 (default: 7).
- Stopbits: Stopbits specified in the manual of the device, e.g., 1 (default: 1).
- Parity: Parity specified in the manual of the device, e.g., No (default: Even).
- FlowControl: FlowControl specified in the manual of the device, e.g., No (default: No).
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
- Bus address: The bus address of the device.
How to Use
On the General page, on the left, you can view general information about the device, such as the Software Version, the Device Name, the Maximum Number of Supported Switches, and the Maximum Number of Supported Chains.
You can also define the mode of the device (using the Global Device Mode parameter) and its respective Control Mode.
On the right, the page shows if there are any Active Alarms, Unacknowledged Alarms, or PSU 1 and PSU 2 Alarms.
On the Switches page, you can view the status of up to four switches in the system. For each switch, the current position, lock state, and alarm state are displayed.