Double D Electronics DDA266
The DDA266 Diversity Controller manages the switchover between two separate uplink sites, according to received signal (beacon) levels.
The Double D Electronics DDA266 connector is used to monitor and control DDA266 Diversity Controllers.
About
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | V1.1x |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Configuration
Connections
IP Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
- Bus address: The bus/unit address of the device.
How to use
The General page displays device name and software version information.
On the Switching Control page, it is possible to change/configure the Control and Operation modes of the device. Note that setting the Operation mode to Automatic will not work in some cases (if both sites are transmitting, if there is a specific (configurable) pattern of switches, or if at least one polarization is not in maintenance mode). On this page, before you try to switch to site 1 or 2, make sure to select the Polarization and Chains that need to be switched.