Table of Contents

Double D Electronics DDA89-12

The connector monitors the activity of the Double D Electronics DDA89-12 controller.

About

The connector has a serial communication to the Double D Electronics DDA89-12 and allows the end user to control and monitor the switches/best route configuration, plus observe the status of the device's converters.

In addition to the previous, the connector uses three timers: 1) one polling every half second for fast varying information from the controllers; 2) one polling every five seconds that retrieves general information from the device and its switches as well; and 3) one that polls every hour for slowly varying information.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x Initial version No Yes

Product Info

Range Supported Firmware Version
1.0.0.x V0.00A 23.02.10

Installation and configuration

Creation

Serial Main connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Direct connection:

    • Baudrate: Baudrate specified in the manual of the device, e.g., 9600.
    • Databits: Databits specified in the manual of the device, e.g., 7.
    • Stopbits: Stopbits specified in the manual of the device, e.g., 1.
    • Parity: Parity specified in the manual of the device, e.g., No.
    • FlowControl: FlowControl specified in the manual of the device, e.g., No.
  • Interface connection:

    • IP address/host: The polling IP of the device.
    • IP port: The IP port of the device.
    • Bus address: The bus address of the device.

Usage

The connector has three pages: 1) General; 2) Switches; and 3) Converters.

General Page

In the general page, the user can observe some general information from the device on the left such as the Unit Type; the Software Version; the Number of Supported Paths; the Number of Switch Banks Fitted.

In addition to the previous, the user can define the device's mode (Global Device Mode) and its respective Control Mode.

At the right of the page the user can observe if there's any existing faults regarding: Active Alarms; Secondary Alarms; and faults in the PSUs (PSU 1 Fault and PSU 2 Fault).

Switches Page

In the Switches Page, the user can configure the status of the active switches from the toggle buttons (Switch 1-12) - plus there is a page button that allows the user the configure/perform the route calculation for the switches themselves in the "Route Calculation..." page button.

Converters Page

In the converters page a table is presented with the device's converters' status with the following information:

  • Converter Index
  • Frequency
  • Attenuation
  • Fitted
  • Mode
  • Mute
  • Inverted Spectrum
  • Auto C/O Logic
  • Input Fault
  • Delayed Fault
  • Comms Fault