Druid Raemis
Raemis is a technology platform by Druid Software that harnesses 5G, 4G, 3G, 2G, and Wi-Fi radios to implement standalone cellular core network solutions.
The Druid Raemis connector monitors this platform, by enlisting active alarms and also implementing a heartbeat mechanism that evaluates the liveliness of the Raemis platform.
About
Version Info
| Range | Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 5.2.6.0-1, rd974ae4 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - |
Configuration
Connections
HTTP Connection - Main
This connector uses an HTTP connection and requires the following input during element creation:
HTTP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (default: 443).
SNMP Connection - Traps
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Initialization
For the HTTP connection, you need to configure the API authentication: go the General page, and configure the Username and Password.
On that same page, you can also configure the proxy server.
Web Interface
The web interface is only accessible when the client machine has network access to the product.
How to use
The Active Alarms table on the Alarms page fetches the information from the REST API.
The heartbeat mechanism is based on receiving a specific, periodic SNMP trap (heartbeat). If the time between heartbeats is greater than the configured Heartbeat Delay parameter, an alarm is raised (with the Heartbeat Status parameter).