The Model D0124S3ULA-22320 is designed to take an incoming 950-2150 MHz signal and split it to twenty-four outputs with a nominal 0dB gain.

This connector displays the status of the power supplies for the ETL Systems 22320 device, retrieved from an element.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x -

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

Virtual connection

This connector uses a virtual connection and does not require any input during element creation.

Configuration of Element Connections

This connector requires a connection to another element for the status of the pins connected to the device. See the table below:

Power Supply Designation Pin No.
PSU 1 COMMON 1
PSU 1 FAIL 2
PSU 1 GOOD 3
PSU 2 COMMON 5
PSU 2 FAIL 6
PSU 2 GOOD 7

The "Fail" and "Good" pins of each power supply must be connected to another element using the Element Connections module available in DataMiner.

Usage

General

This page displays the status of Power Supply 1 and Power Supply 2.