ETL Systems 22420
The ETL Dextra series covers 4-way (single & dual), 8-way (single & dual) and 16-way, active splitters and combiners. They are designed for use in signal distribution systems in the L-Band range 850-2450MHz.
About
This is an SNMP connector that allows two basic functions:
- Monitoring: Polling the device for its current hardware status, including the temperature, voltage and current configuration.
- Configuration: Allowing the configuration of some of the splitter's parameters, namely the IP and the way it works (several modes, paths, etc.).
Version Info
Range | Description | DCF Integration | Cassandra Compliant |
---|---|---|---|
1.0.0.x [SLC Main] | Initial version | Yes | Yes |
Product Info
Range | Supported Firmware Version |
---|---|
1.0.0.x | 1.5 e351 |
Installation and configuration
Creation
SNMP Device connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Usage
General
This page contains the main information and status of the splitter, such as its Name, Location, Temperature.
It also contains a Reboot button. Clicking it will trigger a confirmation message which, if accepted, will force the device to restart. This will cause the device to be temporarily unavailable.
Status
This page displays table containing the Power Supply Status and Amplifier Status, as well as their individual values.
Configuration
This page contains several configuration options related to the splitter, including IP Settings, Trap Settings, LNB Settings and Splitter Mode Settings.
It is important to note the following regarding the way the IP settings work:
The IP configurations entered by the user will only be assumed by the machine once the DHCP option is off.
Once the settings have been saved, the machine will reboot.
Web Interface
This page displays the webpage of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
DataMiner Connectivity Framework
This connector uses the DataMiner Connectivity Framework, or DCF, to allow this element to connect its inputs and outputs to other elements. This is only available on DMA version 8.5.8.5 or higher.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance ask a manager).