Table of Contents

ETL Systems 23116

This connector is used to monitor an ETL Systems 23116 device using the SNMP interface.

The ETL Systems 23116 is a device operating with signals in the L-band range of frequencies of 850-2150 MHz and is designed to provide automatic main/standby switching functions, typically for 2:1 redundancy switching

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version. - -

Product Info

Range Supported Firmware
1.0.0.x Software: E115, v1.8

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP or URL of the destination.
  • IP port: The IP port of the destination.

SNMP Settings:

  • Get community string: The community string used when reading values from the device (default: public).
  • Set community string: The community string used when setting values on the device (default: private).

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

The RF Settings Limits can be configured on the RF page for both main and standby signals. The RF Limits Status parameters on the same page will show if the signals are actually within the configured limits.