ETL Systems M0808C2UFL
The ETL Systems M0808C2UFL is an 8x8 L-band matrix with dual redundant PSUs, a CPU and local control panel. Remote control is possible via a serial or Ethernet connection.
About
With this connector, it is possible to manage general information about the device, and to modify the networking configuration and the matrix configuration itself. The connector also supports traps to detect alarms.
Installation and configuration
Creation
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP Connection
- IP address/host: The polling IP of the device.
SNMP Settings
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device. The default value is public.
- Set community string: The community string used when setting values on the device. The default value is private.
Usage
Once created, the element can be used immediately. There are 5 pages available.
Matrix
On this page, the device matrix can be configured, i.e., the wiring of inputs and outputs.
General
This page contains the relevant information coming from the standard MIB-2, such as the location, system description, etc.
Alarms
This page displays the alarms of the power supply units, alarms of the matrix itself and VTR-10 alarms. These alarms are detected through standard polling or receiving traps. The device sends traps every 5 seconds when one of the components is in alarm state, and stops when the component gets back to normal. The connector sets the alarm state when a trap arrives and checks 5 seconds later if the alarm status was cleared.
Settings
On this page, you can configure the networking options and set who receives the traps issued by the device.
Web Interface
This page displays the web interface of the device.