This connector displays information related to the ETL Systems NGM-21 device.
This connector uses two interfaces to communicate with the NGM-21 device. The SNMP interface is used to retrieve information regarding the chassis temperature and the status of the fans, and the serial interface is used to execute the remaining commands.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version. | - | - |
| 1.0.1.x [SLC Main] | Labels and locks are retrieved via serial communication instead of via SNMP. | 1.0.0.8 | None. The major change was required because unused table columns have been removed from the Output Settings table. |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
| 1.0.1.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
| 1.0.1.x | No | Yes | - | - |
Creation
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP Address/host: The polling IP of the device, e.g., 10.145.1.12.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string required to read from the device. The default value is public.
- Set community string: The community string required to set to the device. The default value is public.
Serial Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
- Type of port: TCP/IP.
- IP address/host: The polling IP or URL of the destination, e.g., 10145.1.12.
- IP port: The port of the destination, e.g., 13000.
- Timeout of a single command: 2500 ms (minimum).
Usage
Main View Page
This page contains the device matrix.
General Page
This page displays generic parameters, such as the version and IP address.
Alarm Page
This page displays the device status, such as temperatures, fan speeds, and communication state.
Configuration Page