This SNMP connector shows the status of the different parameters of an ETL Systems PRN-10.

The ETL Systems PRN-10 is a 1U, 19" rack-mountable chassis with up to 16 DC injector modules fitted at the rear and hot-swappable dual redundant power supplies.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x 1v03

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device, e.g., 10.11.12.13.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string in order to read from the device. The default value is public.
  • Set community string: The community string in order to set to the device. The default value is private.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to Use

The element consists of the data pages detailed below.

Chassis

This page contains information about the chassis and the modules contained within it. This includes the temperature of each module, the 5V status, etc.

There is also a Reboot button, which allows you to perform a soft reboot.

The page contains the following page buttons:

  • IP Settings: Contains a table with information such as the IP address and IP subnet of the device.
  • Trap Settings: Contains a table with trap information such as the Receiver IP Address and Trap Community.

Modules

This page contains the Module Info Table. For each module, it mentions the type, the max voltage and the DC inject voltage status, etc.

The Module Settings page button displays a table with information such as the voltage of the modules, the Current/RF Alarm Level Low/High, etc.

Reference

This page contains the 10 Mhz Info Table, which includes information such as the RF Power, the Amp Current 1, and the Summary Alarm.

The Reference Settings page button displays a table with the 10 Mhz Internal Source setting, and the 10 Mhz Gain.

PSU

This page contains a table with PSU info, including the status, voltage and current.