Table of Contents

Eutelsat Probe Service

This is an enhanced service protocol that allows more efficient alarm monitoring of the parameters included in the service.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x Initial version - -

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

Virtual Connection

This connector uses a virtual connection and does not require any input during element creation.

Initialization

It is possible to create alarms based on parameter values or based on alarm states. In that case, you need to configure the inputs, outputs and thresholds on the Compare Values page.

It is also possible to create alarms based on alarm states. In that case, you need to configure the input and output on the Compare Alarms page.

For more information on how the alarms are generated, refer to the section below.

How to Use

When the Compare Values option is used, you can configure two input (A and B) and two output (X and Y) parameters.

Alarms will be generated based on the following conditions: - if (max(A, B) - min(A, B)) / max(A, B) > threshold a - if (max(X, Y) - min(X, Y)) / max(X, Y) > threshold a - if (max(A, X) - min(A, X)) / max(A, X) > threshold b or (max(A, Y) - min(A, Y)) / max(A, Y) > threshold c - if (max(B, X) - min(B, X)) / max(B, X) > threshold b or (max(B, Y) - min(B, Y)) / max(B, Y) > threshold c

Alarms will be generated based on the following conditions for two inputs (A, B) and one output (X): - if (max(A, B) - min(A, B)) / max(A, B) > threshold a - if (max(A, X) - min(A, X)) / max(A, X) > threshold b - if (max(B, X) - min(B, X)) / max(B, X) > threshold c

When the Compare Alarms option is used, you will receive alarms based on the following table:

Output 1 Output 2 Input 1 Input 2 Alarm Severity Alarm Description
Critical Critical Critical Critical Critical Loss of outputs and inputs
Critical Critical Critical Normal Critical Loss of outputs and input 1
Critical Critical Normal Critical Critical Loss of outputs and input 2
Critical Critical Normal Normal Critical Loss of outputs
Critical Normal Critical Critical Critical Loss of output 1 and inputs
Critical Normal Critical Normal Major Loss of output 1 and input 1
Critical Normal Normal Critical Major Loss of output 1 and input 2
Critical Normal Normal Normal Major Loss of output 1
Normal Critical Critical Critical Critical Loss of output 2 and inputs
Normal Critical Critical Normal Major Loss of output 2 and input 1
Normal Critical Normal Critical Major Loss of output 2 and input 2
Normal Critical Normal Normal Major Loss of output 2
Normal Normal Critical Critical Critical Loss of inputs
Normal Normal Critical Normal Major Loss of input 1
Normal Normal Normal Critical Major Loss of input 2

Notes

This connector was created specifically for Eutelsat.