Table of Contents

EVERTZ 5601ACO2

The 5601ACO2 Automatic Changeovers are intended for use with two 5601MSC Master Clock/Sync Generators. The 5601ACO2 system uses latching relays to ensure maximum reliability and minimal disruption in the event of any failure.

About

This connector uses SNMP to monitor the Evertz 5601ACO2 device.

Installation and configuration

Creation

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP Connection:

  • IP Address/host: The polling IP of the device, e.g., 10.145.1.12.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string required to read from the device. The default value is public.
  • Set community string: The community string required to set to the device. The default value is public.

Usage

General Page

This page displays general information about the device, such as the System Description, Up Time, and Contact. It also displays the Operating Mode, Changeover Rate, Voting Mode, Control Source, etc.

GPO I/O Page

This page contains the GPO Input Table with the Input Status and GPO Output Table with the Output Status.

Analog Faults Page

This page displays the Fault Analog TG Table and the Fault Analog Sync Table. There is a Voting page button for each table, which will display the corresponding voting configuration.

Source Signal Faults Page

This page displays faults related to the source signal, displayed in the 3G/HD/SDI, AES/DARS, 10 MHz, Word Clock and LTC Table. Each table either has a Voting page button, which will display the corresponding voting configuration, or a toggle parameter to configure voting.

Output Faults Page

This page contains output-related faults. The Fault GPO Output Table has a Voting page button, which will display the corresponding voting configuration.

Power/Fan/Door Faults Page

This page displays faults related to the Power Supply, the Fan or the Door.