Table of Contents

Evertz 570FC

This connector can be used to monitor and control the Evertz 570FC frame controller.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x Kernel Major Release: 5.1 Software Build: 1.5 Build 87 Software Build: 1.5 Build 61

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string used when reading values from the device, by default public.
  • Set community string: The community string used when setting values on the device, by default private.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to Use

The element created with this connector has several data pages:

  • The General page displays the uptime, ID, name, and location of the system.
  • On the Product Location, Hardware, Hardware LED, Software, Proxy Configuration and Time Management pages you can find various tables with information and settings related to these subjects.
  • The SNMP Traps and Traps Management pages display tables where you can add/remove traps destination as well as read/change the state and value of traps.