Table of Contents

Factum RSW100

The Factum RSW100 connector displays information related to the Factum RSW100 Redundancy Switch device.

About

This connector uses an SNMP connection to communicate with the Factum RSW100 device.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x Initial version Yes Yes

Product Info

Range Supported Firmware Version
1.0.0.x 2.6.02

Installation and configuration

Creation

SNMP main connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP Connection:

  • IP Address/host: The polling IP of the device, e.g. 10.145.1.12.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string required to read from the device. The default value is public.
  • Set community string: The community string required to set to the device. The default value is public.

Usage

General Page

This page displays status parameters such as the Agent Version, System Contact, Operation Mode, etc.

Alarms Page

This page displays the alarm statuses, such as the Agent Alarm Status, Change-Over Alarm Status, Internal Alarm Status, etc.

DataMiner Connectivity Framework

Version 1.0.0.5 and following of the Factum RSW100 protocol support the usage of DCF and can only be used on a DMA with 8.5.8.5 as the minimum version.

DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).

Connections

Internal Connections

  • If selected input is A, an internal connection is created between input A and the two outputs (output A and output B).
  • If selected input is B, an internal connection is created between input B and the two outputs (output A and output B).