Factum RSW100
The Factum RSW100 connector displays information related to the Factum RSW100 Redundancy Switch device.
About
This connector uses an SNMP connection to communicate with the Factum RSW100 device.
Version Info
Range | Description | DCF Integration | Cassandra Compliant |
---|---|---|---|
1.0.0.x | Initial version | Yes | Yes |
Product Info
Range | Supported Firmware Version |
---|---|
1.0.0.x | 2.6.02 |
Installation and configuration
Creation
SNMP main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP Connection:
- IP Address/host: The polling IP of the device, e.g. 10.145.1.12.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string required to read from the device. The default value is public.
- Set community string: The community string required to set to the device. The default value is public.
Usage
General Page
This page displays status parameters such as the Agent Version, System Contact, Operation Mode, etc.
Alarms Page
This page displays the alarm statuses, such as the Agent Alarm Status, Change-Over Alarm Status, Internal Alarm Status, etc.
DataMiner Connectivity Framework
Version 1.0.0.5 and following of the Factum RSW100 protocol support the usage of DCF and can only be used on a DMA with 8.5.8.5 as the minimum version.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Connections
Internal Connections
- If selected input is A, an internal connection is created between input A and the two outputs (output A and output B).