Foxcom Platinum PL700 Manager
About
This connector can be used to manage and control fiber-optic cards, redundancy switches, power supplies, and communication cards. It uses an SNMP connection to communicate with the device.
The connector supports alarm logging, including transmitter and receiver RF and optical faults. Monitoring features include ambient temperature and RF/optical input and output power, as well as all the usual general parameters available for this type of hardware, such as the part and device number.
This connector exports several other connectors based on the information retrieved from the hardware. The list of exported connectors can be found in the "Exported components" section of this page.
Exported components
| Exported Connector | Description |
|---|---|
| Foxcom Platinum PL700 Manager - PL7011 | Power supply |
| Foxcom Platinum PL700 Manager - PL7220T | Transmission card |
| Foxcom Platinum PL700 Manager - PL7220R | Receiving card |
| Foxcom Platinum PL700 Manager - PL7230T | Transmission card |
| Foxcom Platinum PL700 Manager - PL7230R | Receiving card |
| Foxcom Platinum PL700 Manager - PL7611 | Power supply |
| Foxcom Platinum PL700 Manager - PL7240T | Transmission card |
| Foxcom Platinum PL700 Manager - PL7240R | Receiving card |
| Foxcom Platinum PL700 Manager - PL2 7220R | Receiving card |
| Foxcom Platinum PL700 Manager - PL2 7220T | Transmitting card |
Configuration
Connections
SNMP main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
- Device address: Not required.
SNMP Settings:
- Port number: By default 1610.
- Get community string: public.
- Set community string: private.
Usage
System
This page contains parameters related to the Main Control Processor, such as status, temperature, hardware and software revision.
General
This page contains parameters related to files and commands, such as IP address, download status, progress, and device slot. This information is not exported to the child elements and is only available here. The page contains both the general status and the configuration of system management.
PSU
This page contains power supply information, specifically the alarm status for all the power supplies in the system, as well as output information, specifically the Voltage, Current, and Power output of the system's power supplies.
You can also create DVEs for the PSUs per row level here. With the Create All or Clear All buttons, you can create all DVEs at once or clear them all at once, respectively.
Slots
This page contains all the status and configuration tables for each slot. You can reset the modules here. You can also handle the time configuration for the cards and check their running temperatures, different channel statuses, voltages, and input/output power. Finally, you can also create DVEs for the slot cards per row level.
Modules
This page contains the tables used to export the DVEs. With the Create All or Clear All buttons, you can create all DVEs at once or clear them all at once, respectively.
DataMiner Connectivity Framework
The 1.0.0.1 range of the Platinum PL700 Manager connector supports the usage of DCF.
Connectivity for all exported connectors is managed by this connector.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Virtual fixed interfaces:
- Input interface, type in.
- Output interface, type out.
Connections
Internal Connections
- Between Input and Output interfaces, an internal connection is created.