GatesAir Flexiva M3FM-TX 1P1
The GatesAir Flexiva M3FM-TX is an FM transmission system.
This connector is used to monitor the GatesAir Flexiva M3FM-TX 1P1. It uses SNMP to retrieve and configure the data.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.1.x [SLC Main] | Polling on group changed from hour to min. | 1.0.1.3 | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.1.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.1.x | No | Yes | - | - |
Configuration
Connections
Main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 10.11.12.13.
- Device address: Not used.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device. The default value is public.
- Set community string: The community string used when setting values on the device. The default value is private
Web Interface
The web interface is only accessible when the client machine has network access to the product.
How to Use
The element has the following data pages:
- General: This page displays basic SNMP information. It has two subpages, General Events and DVE Control. The latter contains the Transmitter DVE Table, with the controls for the transmitter DVE.
- Transmitter: Displays a table with the transmitter information and status.
- Configuration: Contains the Transmitter Configuration Table, with information about the transmitter status.
- Events: Displays Transmitter Events Table, with information about events regarding the transmitter.
- System: Contains system information related to the transmitter.