GatesAir Maxiva XTE Exciter

The GatesAir Maxiva XTE Exciter is an exciter that powers over-the-air delivery across the UHF television spectrum.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x 06.00.0034 (PCM Software Version) 01.00.0685 (SNMP Version)

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP or URL of the destination.
  • IP port: The IP port of the destination. The default ports for the device depends on its location:

Slot: Exciter A Port, Exciter B Port

Xmtr #0 : 19617, 19873 Xmtr #1 : 21665, 21921 Xmtr #2 : 23713, 23969 Xmtr #3 : 25761, 26017 Xmtr #4 : 27809, 28065 Xmtr #5 : 29857, 30113 Xmtr #6 : 31905, 32161 Xmtr #7 : 33953, 34209 Xmtr #8 : 36001, 36257

SNMP Settings:

  • Get community string: The community string used when reading values from the device (default: public).
  • Set community string: The community string used when setting values on the device (default: private).

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

With this connector, it is possible to monitor and configure the Exciter cards in the MSC frame. In addition, it is also possible to enable trap notifications.

The communication protocol that is used to get and set the values is SNMP.