This connector uses an SNMP connection to monitor the Huawei iManager U2000.
About
The iManager U2000 Unified Network Management System is designed to efficiently and uniformly manage transport, access, and IP equipment in both the network element (NE) layer and the network layer. The U2000 provides unified management and visual operation and maintenance (O&M) to help operators reduce O&M costs and transform networks to all-IP networks.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 172.32.65.38.
SNMP Settings:
- Port number: The UDP port, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Usage
Filters
This page allows you to set filters, including filters for the Alarms, Alarm Clears, Acknowledge Alarms and Unacknowledged alarms.
Two filters can also be set for the synchronization: Synchronization command start and Synchronization command stop.
Trap Table
This page contains a Traps table, which displays the received traps along with all their bindings. At the top of the page, the page button Trap Table Clear Options opens a subpage page where clearing options can be defined.
Above the table, the Traps number parameter displays the number of traps that are currently in the table.
Web Interface
This page displays the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
Notes
Although the U2000 system from Huawei can implement several different interfaces, this connector only implements the SNMP Interface used to send notifications and alarms (SNMP traps) to third-party systems.