Icareus EP100
The Icareus EPG platform is used by broadcasters and network operators to manage multi-platform EPG on a single integrated platform. It generates all the PSI/SI and EIT tables needed for premium DVB networks or to serve the IPTV/OTT middleware platform.
In the 1.0.0.x range, this connector uses a serial connection to communicate with the device to retrieve important KPIs. In range 1.1.0.x, an SNMP connection is used instead.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x | Initial version. | - | - |
| 1.1.0.x [SLC Main] | Changed from a serial connection to an SNMP connection. | 1.0.0.3 | Existing elements need to be reconfigured before the new connection will be taken in use. |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
| 1.1.0.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
| 1.1.0.x | No | Yes | - | - |
Configuration
Connections
Serial Connection - range 1.0.0.x only
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination. Default port: 22.
SNMP Connection - range 1.1.0.x and later
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination. Default port: 161.
- Bus address: The bus address of the device.
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
How to use
When the element is polling the data, you can check the status information on the General page.