Imagine Communications DAB VAX Single Drive
The Imagine Communications VAX is a DAB digital radio and VHF TV solid-state transmitter built on Harris Broadcast PowerSmart 3D architecture, featuring a full broadband, single-amplifier design.
About
With this connector, it is possible to monitor and configure the transmitter itself, as well as to enable the trap notifications and their priorities.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | a1160 |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Configuration of the LITE functionality
To configure the LITE functionality of the connector, on the Network Settings page, enable the parameter LITE PROTOCOL.
Usage
General
This page includes general information from the standard MIB-2, such as the device location, contact information, system name, uptime, etc..
Transmitter
On this page, you can configure transmitter behavior, such as the operation mode or the input. You can also monitor the state of the transmitter, e.g., the state of the inputs, and check for the presence of alarms and warnings.
Event Settings
On this page, you can enable or disable the traps.
Event priority
This page allows you to configure the priority of the notifications.
Web Interface
This page displays the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
Notes
Note that there are 8 possible notifications that this connector can receive via traps (if enabled). When these traps are received, the corresponding parameters are polled again so their state can be updated.