Imagine Communications OXS+2+OP
The Imagine Communications OXS+2+OP connector combines a serial and smart-serial connection to monitor and configure the Receiver card in an Imagine Communications frame. Alarm monitoring can be activated on all important parameters.
About
With this connector, you can monitor and configure the Imagine Communications card.
Current Version: 1.0.0.1
Installation and configuration
Creation
This is a serial connector combined with smart-serial communication. During the creation of the element, the port settings need to be filled in correctly. These communication settings will be used to send and receive commands and responses to and from the device.
SERIAL MAIN CONNECTION
- IP address/host: UDP/IP: The polling IP of the device, e.g. 172.32.65.38.
- IP port: The IP port of the device, set to the fixed value 4050.
- Bus address: This is a combination of the frame number and slot number/ID: "<frameNumber>.<slotID>" (e.g. frame 1 and slot 12 = bus address 1.12).
SMART-SERIAL PORTDEV CONNECTION
- IP address/host: UDP/IP: The local DataMiner IP to receive responses, e.g. 172.0.0.50.
- IP port: The IP port of the DMA, set to the fixed value 4000.
Usage
Alarms Page
On this page, several alarm parameters are displayed for the two channels (Loss of Signal, Cannot Lock, Signal Alarm and Unsupported Format). The state of the alarms can be Alarm Inactive or Alarm Active. Alarm monitoring is available on these parameters.
Processing Page
This page contains one page button, Other. On this page you can configure the CH01 Bitrate Select and CH02 Bitrate Select. Possible values to set are Auto, 270Mbps, 1.5Gbps, 3Gbps or Bypass.
Status Page
This page contains one page button, Other. On this page you can see the CH01 Signal Strength, CH01 Input Format, CH01 Signal Lock, CH02 Signal Strength, CH02 Input Format and CH02 Signal Lock. Trending is possible on the Signal Strength parameters.
System Page
This page contains one page button, Other. On this page you can view the following parameters: Module Option, Receiver Type and Serial Number. In addition, there is also the License Key parameter, which can be configured.
Web Interface Page
On this page you can access the web interface of the Imagine Communications frame. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
Notes
A serial connector with smart-serial connection means that there has to be a connection to a real device. If there is a change on the device, a response will be pushed to the DMA even if no poll request is sent.