Javit Alarm Monitoring
The Javit Alarm Monitoring system collects sound alarms from various monitoring computers and forwards the alarms as SNMP traps to a central monitoring application. The Javit Alarm Monitoring connector displays a list of all monitoring computers with their current alarm status and delay times.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | No | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination (default: 161).
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Initialization
No extra configuration is needed.
Redundancy
There is no redundancy defined.
How to use
The connector consists of one page, the General page, which contains the Alarm Contact Table.
This table displays a list of all connected monitoring systems with their status parameters, such as System Name, Alarm status, First Delay, Resend Delay and Clear Delay.