Table of Contents

Lancier Monitoring PSC

The Lancier Monitoring PSC is a modernized, fully automatic compressed air system designed for the compression and drying of clean air, primarily for injection into cables and hollow conductors. This system ensures the efficient delivery of dry, compressed air by incorporating advanced control mechanisms and safety features.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version. - -

Product Info

Range Supported Firmware
1.0.0.x V1.19

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Connection - Main

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.

SNMP Settings:

  • IP port: The IP port of the device.
  • Get community string: The community string used when reading values from the device (default: public).
  • Set community string: The community string used when setting values on the device (default: private).

How to Use

Lancier Monitoring PSC is a plug-and-play type of connector.

General Page

The General page displays information about the system, configuration, compressor, and tank.

Time Settings

On the Time Settings page, you can configure the date and time settings of the device.

Operating Hours

On the Operating Hours page, you can configure the operating hours of the device.