Table of Contents

Mitec 18202-01MD Power Switching Controller

This connector displays status and summary information of the Mitec 18202-01MD Power Switching Controller. It also allows the user to execute remote commands to change the configuration of the device.

The Mitec 18202-01MD Power Switching Controller can monitor and control 4 RF Switches.

About

Serial commands are used to retrieve the device information and to execute the settings.

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x Software version 01
Model Number 18202

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Installation and configuration

Creation

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Direct connection:

    • Baudrate: 9600
    • Databits: 7
    • Stopbits: 1
    • Parity: even
    • FlowControl: no
  • Interface connection:

    • IP address/host: The polling IP of the device.
    • IP port: The IP port of the device. This is required. The default value is 14 (8013).
    • Bus address: The bus address of the device. This is required. The default value is 31 (hex).

Usage

General

This page displays the Model Number.

Status

This page displays the Local/Remote Mode, Switch Summary and Power Supply Summary, and finally also the Switch 1, Switch 2, Switch 3, and Switch 4 settings.

The Switch 1, Switch 2, Switch 3 and Switch 4 can be configured by clicking the toggle button under each position.

There are two possible positions for each switch: Position 1 and Position 2.