Table of Contents

Mitsubishi FX3U-ENET-ADP

This connector can be used to monitor and configure an Ethernet interface block FX3U-ENET.

About

The Mitsubishi FX3U-ENET-ADP Ethernet module is an interface module on the PLC side for connecting the FX3G/FX3U/FX3UC series PLC with the host system, such as a personal computer workstation, and other PLCs using the TCP/IP or UDP/IP communication protocol via Ethernet (100BASE-TX, 10BASE-T).

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x -

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Installation and configuration

Creation

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: The polling IP of the device.
    • IP port: The IP port of the device.

Usage

Import CSV

On this page, you can set the file path to read and fill in the respective tables.

Data Register

This page displays the Data Register Table, with values from the device. Depending on the client access (read only or read/write) of the memory address, you can set a new value to that parameter.

Table polling can be enabled or disabled.

Internal Relay

This page displays the Internal Relay Table, with values from the device. Depending on the client access (read only or read/write) of the memory address, you can set a new value to that parameter.

Table polling can be enabled or disabled.

Effekt

On this page, the parameters Engine Effekt Tag and Engine Effekt Reference Tag must be filled in with the corresponding tags from the Data Register Table.

If these parameters have the correct tags, the parameters Effekt and SRW will be calculated as follows:

  • Effekt = Sqrt(Engine Effekt * Engine Effekt Reference ) * 1.126

  • IF Engine Effekt Reference > 0 Then SWR = Engine Effekt / Engine Effekt Reference

    Else

    SWR = 0

    Endif