Table of Contents

Moxa ioLogik E1211

This connector allows you to monitor a configured Moxa ioLogik E1211 device via SNMP. It displays basic information about the device, as well as the status of the existing DO channel. For each DO channel, some settings can also be configured

About

Version Info

Range Key Features Based on System Impact
1.0.0.x Monitoring of DO channels - -

Product Info

Range Supported Firmware
1.0.0.x v3.0

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device, e.g., 10.11.12.13.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string in order to read from the device. The default value is public.
  • Set community string: The community string in order to set to the device. The default value is private.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

General Page

This page displays system information: the total number of channels, server model, system uptime and firmware version.

I/O Status Page

On this page, you can find the DO channel monitor table. These tables allow you to monitor all available DO channels. For the DO channels, you can configure parameters such as type, status, signal pulse ON width, signal pulse OFF width and signal pulse start/stop.

Both tables allow you configure a custom name for each channel. Greyed out entries in the tables are disabled and cannot be set.

Traps

On this page, you can find the Trap Table. This trap table holds all the incoming traps from the device.