Newtec USS0202
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | - Initial version - SNMP parameters and trap processing |
- | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
- Bus address: The bus address of the device.
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
How To Use
The connector uses a retry mechanism to update its tables after changing a cell value.
The parameters that are located on the pages USS Control and USS Operation Config are only relevant for devices with a single protection group. This means that these pages are not useful when multiple protection groups are available.
Note that it can occur that the Group Name column of several tables shows the wrong names. If the names appear to have shifted, go to the USS Setup page and change the Control Group Index parameter. The default value (Check First ID) will instruct the connector to decide how to poll the groups, based on the ID of the first group. The one-based option will poll the groups without incrementing the ID. For example, a group with ID 0 will be polled at //cgi-bin/pegui-cgi/uss0, a group with ID 1 will be //cgi-bin/pegui-cgi/uss1, etc.
Web Interface
The web interface is only accessible when the client machine has network access to the product.