Nokia OMS 1350

The Nokia Optical Management System (OMS) 1350 centralizes multiple network management functions in one unified management system for the entire Nokia optics portfolio.

This connector uses the CORBA protocol to communicate with the Nokia OMS 1350.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x 3.5

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - - Nokia OMS 1350 - Node
- Nokia OMS 1350 - 11DPM8
- Nokia OMS 1350 - 11QPA4
- Nokia OMS 1350 - 32EC2
- Nokia OMS 1350 - AHPHG
- Nokia OMS 1350 - USRPNL

Configuration

Connections

Virtual connection

This connector uses a virtual connection and does not require any input during element creation.

Initialization

In order to use this connector, you must configure the IP Address, Port number, User Name and Password. These parameters can be found on the General page.

In addition, the DLL files IIOPChannel.dll and OMS_1350.dll also have to be placed in the folder "C:\Skyline DataMiner\ProtocolScripts" on the DMA.

Redundancy

There is no redundancy defined.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

On the Overview page, you can find a tree view of the nodes managed by this OMS and the card equipment installed on these nodes.

DVEs can be created for each of the tree view components, which will handle general system parameters and specific alarm information. Creating and deleting DVEs can be done on the Equipment page. A DVE can be created for each managed node, as a virtual representation of the node setup, and for the supported card types. Currently, only the following card types are supported: 11DPM8, 11QPA4, 32EC2, AHPHG and USRPNL.