Novelsat NS2000
The NovelSat NS2000 is a demodulator designed for high-demand satellite reception. The NS2000 delivers significantly higher spectral efficiency compared to DVB-S2.
About
This connector uses SNMP and HTTP communication to monitor and change parameters on the device, to guarantee the efficiency of the equipment.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version. | No | Yes |
| 1.0.1.x | Added DCF integration. | Yes | Yes |
| 1.0.2.x | Monitor Alarm Table with Naming. | Yes | Yes |
| 2.0.0.x | Added HTTP connection. | Yes | Yes |
| 2.1.0.x [Obsolete] | New firmware based on 2.0.0.x. | Yes | Yes |
| 2.1.1.x [SLC Main] | Changes implemented to display keys. | Yes | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 2.1.1.x | 1.1.1 [Build 4761] |
Configuration
Connections - 1.0.0.x/1.0.1.x/1.0.2.x
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- IP port: The IP port of the device (default: 161).
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Connections - 2.0.0.x/2.0.1.x/2.1.1.x
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- IP port: The IP port of the device (default: 161).
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
HTTP Secondary Connection
This connector uses an HTTP connection and requires the following input during element creation:
HTTP CONNECTION:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
- Device address: The device address (default: BypassProxy).
Firmware Configuration
When the element has been created, specify the correct device firmware on the System page. This value can be saved, so that you do not need to specify it again if the element is restarted or stopped.
Usage
System
This page contains general information related to the device, such as the Firmware Version, OS Version and HW Product Type.
In the Firmware Device box, you can select the firmware version of the device. The correct firmware version must be selected in order to ensure that the connector functions correctly.
System Config
On this page, you can configure the device, for example with the DHCP toggle button, the Serial Port settings and the Clock Source toggle button.
There is also a page button that allows you to modify the date and time of the device.
Line Config
This page contains demodulator settings, including Line Mode, RF Frequency, LNB Control, ACM Mode and Symbol Rate.
Channel Config
This page contains demodulator channel settings. For both channels, you can check and configure the Range From and Range to.
Interface Config
This page contains three tables with demodulator interface information (Test, ASI and Ethernet). You can configure various parameters, such as DIT Source, DIA Data Rate and DEI Source.
Line Monitoring
This page allows you to monitor demodulator information and provides a detailed overview of the configuration of the demodulator.
Channel Monitoring
This page contains the Demodulator Line Channel Table.
Interface Monitoring
This page contains demodulator interface information.
Alarm / Event Monitoring
This page contains two tables with alarms and events of the demodulator, respectively.
The Monitor Alarm Table provides an overview of alarm information for the device. The Monitor Events Table takes approximately 2 minutes to be polled. Polling for this table can be disabled with the Poll Monitor Events toggle button. You can also poll the table on demand with the Refresh Events button.
System Monitoring
This page contains information such as the FPGA Temperature, System Board Temperature and Type of Clock Source.
DRM
This page contains DRM information: System DRM Private Key Table, System DRM Remotes AES Table, System DRM Local AES Table, System DRM Activate Key AES Table and System DRM Entitlement Table.
Web Interface
This page provides access to the web interface of the device (http:// Port 80). This may require access credentials (user name/password). Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.
DataMiner Connectivity Framework
The 2.1.1.x connector range of the connector supports the usage of DCF.
Interfaces
Fixed interfaces
Virtual fixed interfaces:
- L-band (in)
- ASI1 (out)
- AS2 (out)
Connections
Internal Connections
- Between L-Band and ASI1
- Between L-Band and ASI2