Paradise RCP-1200
About
This connector can be used to monitor and control any Paradise RCP-1200 device. A TCP/IP connection is used to retrieve and configure the settings of the device.
Configuration
Connections
This connector uses a serial connection and requires the following input during element creation:
- Type of port: The type of port of the connection. By default: TCP/IP.
- IP address/host: The polling IP of the device. For instance: 10.1.48.70.
- IP port: The IP port of the device. By default: 4012.
- Bus address: The source address of the device, within the range 0–31. For instance: 06.
Usage
Fault Status
The following fault status information is shown for the device:
- Summary Fault: Indicates whether a system-wide fault has occurred (amplifiers, processor, power supplies, RF switches).
- PS: Displays whether the power supply is Faulted or Normal.
- RF Switch: Displays whether the position of the switch is set to POS1 or POS2.
- Fault Monitoring
- (External) Amplifier Power: Displays whether the external amplifier is Faulted or Normal.
- External UID: Displays the status of external user-defined inputs (e.g., Normal or Fault).
System Setup
The following control settings are available for the device:
- Panel/Remote Mode
- Auto/Manual Mode
- Amplifier Standby
- Priority
- Buzzer
- Communication: Displays the Unit Address, Serial Baud Rate, Communication Protocol, Unit Hierarchy, and System Redundancy.