Pro-Bel SW-P-08 (2.0.X)
About
Pro-Bel SW-P-08 is used to communicate with routers that implement general remote control protocol SW-P-08. It allows management and monitoring of crosspoints.
Configuration
Connections
Smart-Serial Connection
This connector uses a smart-serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
- Accepted IP address: The IP of the device from which to accept messages.
The following values are defined by the protocol documentation and are set as defaults:
- Baudrate: Baudrate specified in the documentation (default: 9600).
- Databits: Databits specified in the documentation (default: 8).
- Stopbits: Stopbits specified in the documentation (default: 1).
- Parity: Parity specified in the documentation (default: No).
- FlowControl: FlowControl specified in the documentation (default: No).
How to Use
The element has the following data pages: General and Router Control.
General
This page contains the following parameters:
- Matrix Configuration status: Displays any detected misconfigurations. The status OK indicates that the matrix has been successfully configured.
- Number of Sources: Allows you to configure the number of sources for the matrix.
- Number of Destinations: Allows you to configure the number of destinations for the matrix.
- Matrix Number: Allows you to configure the matrix number.
- Level Number: Allows you to configure the level number.
- Source Names Length: Allows you to configure the name length for sources.
- Destination Names Length: Allows you to configure the name length for destinations.
Router Control
This page contains the Sources and Destinations tables, which contain information about the respective sources and destinations.
Notes
The minimum required DataMiner version for this connector is 10.3.0.0 - 12752.