Puregas P550W
With this connector, you can gather and view information from the Puregas P550W device, a dehydrator.
About
The Puregas P200W connector is used to monitor and control a Puregas P550W device. It provides an overview of the different parameters of the device along with its statuses and generated alarms.
The connector uses SNMP to retrieve the data from the device. All parameters are polled every 15 seconds.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | P550W(P012300V20) Dryer, Version 3.00 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 10.11.12.13.
- Device address: Not required.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device. The default value in the connector is public.
- Set community string: The community string used when setting values on the device. The default value in the connector is private.
Usage
General
On this page, you can find general information, such as the Model Number, the Current Firmware Version and Device ID and the Current Date Time.
Status
This page displays the status of the following parameters: Outlet Pressure, Tank Pressure, Humidity, Outlet Flow, Cabinet Temperature, Total Run Time, Last Run Time, System Status, Compressor Status, Fan Status and Heater Status
Alarms
On this page, you can check if there is an alarm on the following parameters: High Flow Alarm, High Out Pressure, Low Out Pressure, High Humidity Alarm, High Cabinet Temperature, High Compressor Last Run Alarm, Maintenance Required, Total Alarm and P550 W Trap
Configuration
On this page, you can configure the system setup, for instance with the Start Up Delay and the Alarm Delay. For the alarm setup, you can configure the High Flow, High Pressure, Low Pressure, High Humidity, High Compressor Last Run and Total Run Time Reset.
The page also displays network setup parameters, such as IP Address, Subnet Mask, Gateway Address and SNMP Trap Server.
Web Interface
This page provides access to the web interface provided by the device's web server. The client machine has to be able to access the device. If not, it will not be possible to open the web interface.